Battery test systems since 1998
From µA cells to 3000 V packs,one test platform.
Cyclers, chambers, fixtures and software for labs that have to defend their data, specified by voltage, current and channel count.
- Voltage
- 5–3000 V
- Current
- 0.1 mA–2000 A
- Records
- 10–1000 Hz

Charge-discharge trace · illustrative
Pick a voltage class
Three classes, one control platform. Start where your device sits.
5 V / 6 V
Cell testers
0.1 mA to 2000 A
Single-cell testing covers material screening, cell design verification, formation studies and cycle life. The class spans microamp leakage channels to 2000 A high-current channels.
20 V to 200 V
Module testers
20 A to 1200 A
Module testing validates series-connected cells, busbars, sensing harnesses and thermal paths before a pack is assembled. Voltage ceilings run from 20 V to 200 V.
300 V to 3000 V
Pack testers
Up to 1200 A
Pack testing covers performance, safety screening and end-of-line sequences at 300 V to 3000 V, including 800 V platforms and megawatt charging profiles.
Range
What we build
Testers, chambers, fixtures, auxiliary channels and the software that ties them together.

Battery test equipment
Cell, module and pack testers with four-wire sensing and programmable protocols.
View range
Environmental chambers
Temperature and humidity chambers wired to the same channel control as the testers, so a thermal step and an electrical step are one programme.
View range
Accessories and fixtures
Fixtures hold the cell, carry the current and define the contact resistance. They decide whether a measurement describes the cell or the rig.
View range
Auxiliary modules
Controllers, auxiliary channels, calibration modules, voltmeters, ammeters and BVIR units extend a tester into a measurement system.
View range
Automatic production
Formation, grading and end-of-line automation for coin, pouch, cylindrical and prismatic cells, built around the same test platform.
View range
Software
The BTS platform defines the test, runs it across hundreds of channels and returns data in a form an engineer can defend.
View rangeSelection
Select by voltage, current and channel count
Three steps, one matching configuration. Then send it to our team.
Find my testerStep 1 · Voltage class
1998
Founded
Battery testing since the first cycler
60,000+
Clients worldwide
550,000+
Units shipped
1,000+
Patents and software copyrights
Company figures as published by NEWARE.
Why NEWARE
What you actually get
Five things that decide whether a test programme still holds up in year three.
Measurement you can defend
±0.02% F.S. current accuracy, four-wire sensing and tabular records. Numbers are separated from units, and every specification is traceable to a datasheet.
One stack from cell to pack
Cell, module and pack testing on the same control software, with chambers, fixtures and auxiliary channels from the same supplier.
Energy back to the loop
Regenerative operation on high-current series returns 75% to 94% of discharge energy at full load instead of heating the room.
Service that reaches the bench
Fremont, Aachen and Hong Kong, with calibration modules so a channel can be verified without removing the cabinet from service.
Data that leaves cleanly
Excel, CSV and TXT export plus report layouts that separate circulation, working and record layers, tied to channel, cell and campaign.

- CT/CE-4000
- 5 / 6 / 10 / 20 V
- CT/CE-8000
- 5 V
- CT/CE-9000
- 5 V
Applications
Where these systems run
Representative scenarios from four kinds of test programme.
Material research
Material screening that survives peer review
Cell and battery manufacturing
Formation and grading that a line can rely on
Automotive and EV
From 400 V modules to 800 V packs
Energy storage
Cycle life claims need a test bench behind them
Coverage
Who supports you locally
Five offices, one service model, calibration and spares.
Shenzhen
Neware Technology Limited
Head office for engineering, manufacturing and global service coordination.
Fremont
Neware Technology LLC
Sales engineering, commissioning and calibration support for US and Canadian accounts.
Aachen
Neware Technology GmbH
Application engineering and service coordination across the European Union.
Seoul
Neware Technology Co., Ltd
Korean sales, installation and local spare-part stock for battery and automotive accounts.
Yokohama
Neware Technology Limited (新威技術株式会社)
Japanese technical support, demonstration units and calibration coordination.
Hong Kong
Neware Technology Limited
Manufacturing liaison, export documentation and global spare parts.
Representative coverage
Calibration, spares and field service
Insights
Technical notes
Methods, specifications and the measurement details that change a result.
2026-10-29
Technology
Minimum pulse width decides whether your DCIR data is usable
A pulse shorter than the instrument response is not a pulse, it is an artefact. Here is how pulse width, acquisition rate and response time interact when you measure internal resistance.
2026-10-12
Technology
GITT or PITT: choosing a diffusion method for your electrode
Both methods estimate diffusivity from a relaxation response. The difference is which quantity you hold constant, and that difference decides which electrode chemistries the result can be trusted for.
2026-09-24
Product
What changes when a 5 V cycler becomes a 200 A module tester
Cabling, cooling, safety interlocks and data volume all change at module scale. A short guide to the specification lines that matter when you move up a voltage class.
Request a technical consultation
Tell us the device, the voltage ceiling and the shortest pulse in your plan. You get a series, a configuration and a lead time.