Temperature and humidity

Environmental chambers

Cycling data only means something at a stated temperature. Chambers are offered as standalone volumes or integrated all-in-one systems where the cycler and the chamber share one control path, so a cell can be cycled from -40 °C to 150 °C without a second data logger.

Environmental chambers in a battery testing laboratory

Environmental test chambers

Charge-discharge and temperature control in one system

The all-in-one testing system integrates the battery tester with the environmental chamber, so a cell can be cycled, rested and aged without leaving the controlled volume and without a second data logger. Fast switching between thermal states, high-precision control and independent zone management shorten the test cycle while keeping the record on one timebase.

Broad temperature coverage

From a 0 °C reference volume to a -70 °C to 150 °C profile range, with volumes from 20 L to 800 L.

Multi-zone design

Dual-zone and four-zone cabinets run independent set-points per zone, so parallel campaigns share one footprint.

Rapid thermal switching

Heating and cooling times are specified per volume, shortening the transition between test conditions.

High-precision control

Temperature fluctuation within ±1 °C (0.5 °C on wide-range models), with deviation of ±2 °C.

Intelligent operation

Touchscreen parameter setting, live monitoring, data collection, remote control and data processing.

Safety design

Alarm system, automatic explosion-proof pressure relief, over-temperature protection and a double-lock structure.

All-in-one systems can be customised by voltage, current and channel count. Volume, channel density and temperature range are fixed together at configuration.

01 · 0 to 85 °C · 25 L to 500 L

Constant temperature all-in-one cabinet in a battery testing laboratory
Temperature
0 to 85 °C
Volume
25 L to 500 L

Constant temperature all-in-one

Stable set-point volumes for long-duration reference testing

A stable, uniform temperature for routine battery performance and life testing. These cabinets hold one set-point for the duration of a campaign, which suits capacity evaluation, cycle life and DCIR work where the variable under study is the cell, not the climate.

Repeatable thermal distribution

Uniform airflow keeps sample-to-sample conditions consistent across a full tray of cells.

Long-duration stability

Temperature fluctuation within ±1 °C and deviation of ±2 °C across week-long cycling campaigns.

Formats and channels

Coin, cylindrical, pouch and prismatic fixtures, from 16 to 160 channels in one cabinet.

Dual-zone and four-zone options

Two 100 L zones or four 25 L zones, each controlled independently, for parallel protocols.

ModelVolumeTemperatureChannels / rack
WHW-25L+15C-16CH25 L15 to 60 °C16
WHW-25L+15C-32CH25 L15 to 60 °C32
WHW-200L-0C-160CH200 L0 to 60 °C160
WHW-200L-0C-80CH200 L0 to 60 °C80
WHW-200L2-0C-160CH100 L × 20 to 60 °C160
WHW-500L-5V6A80CH-380V500 L0 to 60 °C80
Solid-state battery researchConsumer electronics cellsBattery materials researchQuality assurance and incoming inspection

02 · -70 to 150 °C · 20 L to 800 L

High and low temperature all-in-one cabinet in a battery testing laboratory
Temperature
-70 to 150 °C
Volume
20 L to 800 L

High and low temperature all-in-one

Wide-range thermal environments for qualification and safety work

Wide-range cabinets cycle between sub-zero and elevated temperatures to expose performance limits, degradation behaviour and safety characteristics. Cooling is regulated directly rather than compensated by heaters, which lowers power consumption and holds stability through the transition.

Three low-end options

Each volume is offered at -20 °C, -40 °C or -70 °C, all with a 150 °C ceiling.

Thermal cycling and accelerated aging

Programmed high-low transitions for reliability, accelerated aging and thermal stress screening.

Direct cooling regulation

Refrigeration is modulated directly, avoiding heater compensation and reducing steady-state power draw.

Test-system space inside

Rack space for 2 U to 32 U of tester channels is reserved inside the chamber, wired through one control path.

ModelVolumeTemperatureChannels / rack
WGDW-20L-20C-220V-2U20 L-20 to 85 °C16
WGDW-100L-20C-380V-5U100 L-20 to 150 °C5 U
WGDW-100L-40C-380V-5U100 L-40 to 150 °C5 U
WGDW-100L-70C-380V-5U100 L-70 to 150 °C5 U
WGDW-200L-40C-380V-6U200 L-40 to 150 °C6 U
WGDW-400L2-40C-380V-12U-B200 L × 2-40 to 150 °C12 U
WGDW-800L2-40C-380V-32U-B400 L × 2-40 to 150 °C32 U
EV battery manufacturingEnergy storage systemsAdvanced materials researchSafety and abuse testing

01

All-in-one testing systems

Cycler and chamber in one cabinet, from 18 L benchtop to 800 L walk-in.

02

Constant temperature chambers

Stable set-point volumes for long-duration reference testing.

03

High and low temperature chambers

-40 °C to 150 °C for reliability, cycle life and safety screening.

04

Explosion-proof chambers

Reinforced volumes with venting for abuse and thermal-runaway work.

Hardware in this family

Perforated safety cabinet for cell storage and testing
Perforated safety cabinet for cell storage and testing

Specifications are indicative and subject to confirmation against the current datasheet.

Integration with the test platform

One control path for temperature and electrical load

Fixture trays sized to coin, cylindrical, pouch and prismatic formats

Safety interlocks carried into the test sequence

Representative layout. Final configuration depends on channel count, cell format and site conditions.

Request a technical consultation

Tell us the device, the voltage ceiling and the shortest pulse in your plan. You get a series, a configuration and a lead time.

Environmental chambers

  1. 01Complete the form
  2. 02Your mail client opens addressed to ada.kwok@neware.net
  3. 03Send it, and reply directly to Ada