Five series on the attributes that decide the purchase: range, accuracy, dynamics, channels and energy.
| Attribute | CT/CE-4000 The routine cell cycling platform Browse series → | CT/CE-8000 Portable measurement where the cell already is Browse series → | CT/CE-9000 Transient detail at 1000 Hz Browse series → | CT/CE-5000 High current with energy recovery Browse series → | CE-6000 Module, pack and end-of-line Browse series → |
|---|---|---|---|---|---|
| Voltage ranges | 5 / 6 / 10 / 20 V | 5 V | 5 V | 5 / 10 / 20 / 24 / 30 V | 5 V to 3000 V |
| Current ranges | 10 mA to 30 A | 100 mA to 1500 A | 5 A to 13 A | 100 mA to 7200 A | 20 A to 1200 A |
| Lowest discharge voltage | -5 V / 0 V / 1 V / 1.5 V / 2 V | 0 V / 2.5 V | -5 V / 0.7 V | -5 V to 2.5 V | -10 V to 30 V |
| Voltage accuracy | ±0.01% to ±0.1% F.S. | ±0.01% to ±0.05% F.S. | ±0.02% F.S. | ±0.02% F.S. | ±0.01% to ±0.05% F.S. |
| Current accuracy | ±0.02% to ±0.1% F.S. | ±0.02% to ±0.05% F.S. | ±0.02% F.S. | ±0.02% to ±0.05% F.S. | ±0.05% F.S. |
| Power factor | ≥99% at full load | ≥99% at full load | ≥99% at full load | ≥99% at full load | ≥99% at full load |
| Record frequency | 10 Hz | 100 Hz | 1000 Hz | 100 Hz | 100 Hz |
| Min. pulse width | 500 ms | 100 ms / 500 ms | 400 µs | — | 100 ms |
| Current response | ≤20 ms to ≤500 µs | ≤5 ms / ≤10 ms | ≤100 µs | ≤20 ms / ≤30 ms / ≤1 ms | ≤3 ms / ≤5 ms |
| Charge-discharge switch | ≤40 ms / ≤25 ms | ≤20 ms | 35 ms | ≤20 ms / ≤30 ms / ≤2 ms | ≤6 ms / ≤10 ms |
| Parallel capability | Four channels above 50 A | Two adjacent channels | Not supported | Parallel from 75 A upward | Up to four channels |
| Energy feedback | — | ≥65% at full load | — | ≥80% at full load | >75% / >90% / >94% at full load |
| Loop nesting | ≤3 layers | ≤3 layers | ≤4 layers | ≤4 layers | ≤3 layers |
| Steps per process | 254 | 254 | 255 | 255 | 254 |
| Communication | TCP/IP, CAN, RS-485, BMS | TCP/IP, CAN, RS-485, BMS | TCP/IP, CAN, RS-485, BMS | TCP/IP, network expansion | TCP/IP, CAN, RS-485, BMS |
| Working temperature | 0 to 40 °C | 0 to 40 °C | 25 ±5 °C for accuracy | 25 ±10 °C for accuracy | -10 to 40 °C |
| Protection level | IP20 | IP20 | IP20 | IP20 | IP20 |