Voltage
5 / 6 / 10 / 20 V
Current
10 mA to 30 A
Accuracy
±0.02% F.S.
Series
CT/CE-4000
The routine cell cycling platform
The workhorse of material screening and cell design verification. Four current ranges per unit, eight independent channels and a four-wire connection give labs a predictable platform for long cycle-life campaigns, with the throughput and channel density needed to run hundreds of cells at once.
- Voltage
- 5 / 6 / 10 / 20 V
- Current
- 10 mA to 30 A
- Accuracy
- ±0.02% F.S.
- Record
- 10 Hz
4 models in this series
Compare models →BTS-4008Q-5V100mA
Microamp-range cycling for coin cells and separator studies, with negative discharge voltage for symmetric and three-electrode work
Microamp-range cycling for coin cells and separator studies, with negative discharge voltage for symmetric and three-electrode work.
- Max. voltage
- 5 V
- Current ranges
- 0.1 mA / 1 mA / 10 mA / 100 mA
- Accuracy
- ±0.02% F.S.
BTS-4008Q-5V6A
General-purpose cell cycling for cylindrical and small pouch cells in routine capacity and cycle-life programmes
General-purpose cell cycling for cylindrical and small pouch cells in routine capacity and cycle-life programmes.
- Max. voltage
- 5 V
- Current ranges
- 100 mA / 500 mA / 3 A / 6 A
- Accuracy
- ±0.02% F.S.
BTS-4008Q-5V15A
Fast-charge and moderate pulse work on consumer cells, with a shorter minimum pulse for dynamic protocols
Fast-charge and moderate pulse work on consumer cells, with a shorter minimum pulse for dynamic protocols.
- Max. voltage
- 5 V
- Current ranges
- 300 mA / 3 A / 6 A / 15 A
- Accuracy
- ±0.02% F.S.
BTS-4008Q-5V30A
High-rate cycling for power cells where charge acceptance and DCIR dominate the test plan
High-rate cycling for power cells where charge acceptance and DCIR dominate the test plan.
- Max. voltage
- 5 V
- Current ranges
- 1 A / 6 A / 12 A / 30 A
- Accuracy
- ±0.02% F.S.
Specifications are indicative and subject to confirmation against the current datasheet.
Compatible chambers
Temperature and humidity chambers wired to the same channel control, with cable pass-through sized to the fixture.
OpenFixtures and accessories
Cell holders per format, clamps, busbars and auxiliary voltage taps, matched to the channel layout.
OpenSoftware
Protocol authoring, per-channel records and export across the circulation, working and record layers.
OpenSpecifications for this series
DownloadsCT/CE-4000 series
11 files · 5 V / 6 V cell testers · 8 channels per unit
- CT-4008Q-5V12A-204PDF · 0.32 MB · issued 2023-02-21
- CT-4008Q-5V6A-164PDF · 0.21 MB · issued 2023-02-21
- CT-4008Q-5V12A-S1PDF · 0.32 MB · issued 2023-02-21
- CT-4008Q-5V6A-S1PDF · 0.30 MB · issued 2023-02-21
- CT-4008Q-5V100mA-124PDF · 0.29 MB · issued 2022-12-07
- CT-4008T-5V6A-S1-164PDF · 0.39 MB · issued 2022-12-21
- CT-4008-5V20A-NA-S1PDF · 0.22 MB · issued 2024-01-13
- CE-4008Q-5V30A-SRPDF · 0.15 MB · issued 2026-03-16
- CE-4008Q-5V20A-SRPDF · 0.19 MB · issued 2025-08-07
- CE-4008Q-5V15APDF · 0.15 MB · issued 2024-10-09
- CE-4008-20V10A-SRPDF · 0.19 MB · issued 2025-08-06
Files are hosted here for reference. Confirm the revision against the model code you are ordering.
Datasheets for this series are issued by configuration. Add the model code to the request.
DownloadsAdjacent series
Request a technical consultation
Tell us the device, the voltage ceiling and the shortest pulse in your plan. You get a series, a configuration and a lead time.
CT/CE-4000